{"id":4677,"date":"2020-09-18T18:21:16","date_gmt":"2020-09-19T00:21:16","guid":{"rendered":"https:\/\/ddmgaragedoors.com\/blog\/?p=4677"},"modified":"2023-06-23T15:09:16","modified_gmt":"2023-06-23T21:09:16","slug":"setting-voltages-on-single-phase-liftmaster-operators","status":"publish","type":"post","link":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/","title":{"rendered":"Setting Voltages on Single Phase LiftMaster Operators"},"content":{"rendered":"\n<p>Installers and salesmen order sectional door operators to match the operator voltages to the voltages in the buildings. Sometimes salesmen order operators with the wrong voltage, and then need to change the operator voltage.  This can be done by changing the wires at the motor, as long as the building voltage is 110 or 220 volts. The installer should also change the transformer so that the primary voltage matches the building voltage.<\/p>\n\n\n\n<p>Rather than manufacture one operator for 110 volts and one for 220 volts, <a href=\"https:\/\/ddmgaragedoors.com\/blog\/2023\/06\/17\/liftmaster-garage-door-openers\/\">LiftMaster<\/a> designed dual voltage operators. This simplified the process of setting voltages on single-phase <a href=\"https:\/\/ddmgaragedoors.com\/parts\/liftmaster-commercial-operators.html\">LiftMaster operators<\/a>. By doing this, they were able to cut their warehouse inventory in half for the two voltages. And, for the &#8220;oops&#8221; events where an installer doesn&#8217;t realize the difference until he has installed the unit with the wrong voltage, the solution is simply a matter of unplugging a wiring harness connector from one socket and plugging it into an adjacent socket.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg\" alt=\"The two plugs next to the Logic 5 control board; the one on the left is 110, while the one on the right is 220\" class=\"wp-image-5138\" width=\"254\" height=\"254\" srcset=\"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg 279w, https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages-150x150.jpg 150w\" sizes=\"auto, (max-width: 254px) 100vw, 254px\" \/><\/a><figcaption class=\"wp-element-caption\">The socket on the left is for 110 volts, while the empty socket on the right is for 220 volts.<\/figcaption><\/figure>\n\n\n\n<p>LiftMaster achieved this design by installing a dual voltage transformer with wiring harnesses running from the <a href=\"https:\/\/youtu.be\/un_WOtwN3qE\">logic control board<\/a> to the power supply. In the image below, either 110 or 220 volts will work. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2020\/09\/Set-Voltage-on-LiftMaster-Single-Phase-Opener.jpg\" alt=\"Voltage diagram: 110 or 220 volts AC feed into a transformer, which sends 24 volts AC to the Logic Board. The Logic Board sends out 5 volts DC\" class=\"wp-image-4680\" width=\"563\" height=\"313\" srcset=\"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2020\/09\/Set-Voltage-on-LiftMaster-Single-Phase-Opener.jpg 694w, https:\/\/ddmgaragedoors.com\/blog\/uploads\/2020\/09\/Set-Voltage-on-LiftMaster-Single-Phase-Opener-300x167.jpg 300w\" sizes=\"auto, (max-width: 563px) 100vw, 563px\" \/><figcaption class=\"wp-element-caption\"><strong>Setting voltages on single-phase LiftMaster operators is simple with dual voltage transformers and the Logic 5 control boards.<\/strong><\/figcaption><\/figure>\n\n\n\n<p>More information can be found on our YouTube channel. <\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"How To Set the Voltage On a Single Phase LiftMaster Operator\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/ijFTr12rwJ8?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Installers and salesmen order sectional door operators to match the operator voltages to the voltages in the buildings. Sometimes salesmen order operators with the wrong voltage, and then need to change the operator voltage. This can be done by changing the wires at the motor, as long as the building voltage is 110 or 220 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[346,3986,4648,4643],"class_list":["post-4677","post","type-post","status-publish","format-standard","hentry","category-technical-support","tag-diy-instructions","tag-liftmaster","tag-logic-5-control-board","tag-operator-voltage"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.2 (Yoast SEO v25.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Setting Voltages on Single Phase LiftMaster Operators - DDM Garage Doors Blog<\/title>\n<meta name=\"description\" content=\"Setting voltages on single-phase LiftMaster operators is simple with dual voltage transformers and the Logic 5 control boards.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Setting Voltages on Single Phase LiftMaster Operators\" \/>\n<meta property=\"og:description\" content=\"Setting voltages on single-phase LiftMaster operators is simple with dual voltage transformers and the Logic 5 control boards.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/\" \/>\n<meta property=\"og:site_name\" content=\"DDM Garage Doors Blog\" \/>\n<meta property=\"article:published_time\" content=\"2020-09-19T00:21:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-06-23T21:09:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg\" \/>\n<meta name=\"author\" content=\"Dan Musick\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dan Musick\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/\",\"url\":\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/\",\"name\":\"Setting Voltages on Single Phase LiftMaster Operators - DDM Garage Doors Blog\",\"isPartOf\":{\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg\",\"datePublished\":\"2020-09-19T00:21:16+00:00\",\"dateModified\":\"2023-06-23T21:09:16+00:00\",\"author\":{\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/#\/schema\/person\/6b44055c953f4d8e99a57a40629a35c8\"},\"description\":\"Setting voltages on single-phase LiftMaster operators is simple with dual voltage transformers and the Logic 5 control boards.\",\"breadcrumb\":{\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#primaryimage\",\"url\":\"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg\",\"contentUrl\":\"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg\",\"width\":279,\"height\":279},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/ddmgaragedoors.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Setting Voltages on Single Phase LiftMaster Operators\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/#website\",\"url\":\"https:\/\/ddmgaragedoors.com\/blog\/\",\"name\":\"DDM Garage Doors Blog\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ddmgaragedoors.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/#\/schema\/person\/6b44055c953f4d8e99a57a40629a35c8\",\"name\":\"Dan Musick\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ddmgaragedoors.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/39ba49d329ac199e8ea3e6b974179f28cc162d6220a90864760c29295bc9ccaa?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/39ba49d329ac199e8ea3e6b974179f28cc162d6220a90864760c29295bc9ccaa?s=96&d=identicon&r=g\",\"caption\":\"Dan Musick\"},\"sameAs\":[\"http:\/\/ddmgaragedoors.com\"],\"url\":\"https:\/\/ddmgaragedoors.com\/blog\/author\/dan\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Setting Voltages on Single Phase LiftMaster Operators - DDM Garage Doors Blog","description":"Setting voltages on single-phase LiftMaster operators is simple with dual voltage transformers and the Logic 5 control boards.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/","og_locale":"en_US","og_type":"article","og_title":"Setting Voltages on Single Phase LiftMaster Operators","og_description":"Setting voltages on single-phase LiftMaster operators is simple with dual voltage transformers and the Logic 5 control boards.","og_url":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/","og_site_name":"DDM Garage Doors Blog","article_published_time":"2020-09-19T00:21:16+00:00","article_modified_time":"2023-06-23T21:09:16+00:00","og_image":[{"url":"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg","type":"","width":"","height":""}],"author":"Dan Musick","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Dan Musick","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/","url":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/","name":"Setting Voltages on Single Phase LiftMaster Operators - DDM Garage Doors Blog","isPartOf":{"@id":"https:\/\/ddmgaragedoors.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#primaryimage"},"image":{"@id":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#primaryimage"},"thumbnailUrl":"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg","datePublished":"2020-09-19T00:21:16+00:00","dateModified":"2023-06-23T21:09:16+00:00","author":{"@id":"https:\/\/ddmgaragedoors.com\/blog\/#\/schema\/person\/6b44055c953f4d8e99a57a40629a35c8"},"description":"Setting voltages on single-phase LiftMaster operators is simple with dual voltage transformers and the Logic 5 control boards.","breadcrumb":{"@id":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#primaryimage","url":"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg","contentUrl":"https:\/\/ddmgaragedoors.com\/blog\/uploads\/2022\/10\/two-sockets-with-differing-voltages.jpg","width":279,"height":279},{"@type":"BreadcrumbList","@id":"https:\/\/ddmgaragedoors.com\/blog\/2020\/09\/18\/setting-voltages-on-single-phase-liftmaster-operators\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ddmgaragedoors.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Setting Voltages on Single Phase LiftMaster Operators"}]},{"@type":"WebSite","@id":"https:\/\/ddmgaragedoors.com\/blog\/#website","url":"https:\/\/ddmgaragedoors.com\/blog\/","name":"DDM Garage Doors Blog","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ddmgaragedoors.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/ddmgaragedoors.com\/blog\/#\/schema\/person\/6b44055c953f4d8e99a57a40629a35c8","name":"Dan Musick","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ddmgaragedoors.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/39ba49d329ac199e8ea3e6b974179f28cc162d6220a90864760c29295bc9ccaa?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/39ba49d329ac199e8ea3e6b974179f28cc162d6220a90864760c29295bc9ccaa?s=96&d=identicon&r=g","caption":"Dan Musick"},"sameAs":["http:\/\/ddmgaragedoors.com"],"url":"https:\/\/ddmgaragedoors.com\/blog\/author\/dan\/"}]}},"_links":{"self":[{"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/posts\/4677","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/comments?post=4677"}],"version-history":[{"count":14,"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/posts\/4677\/revisions"}],"predecessor-version":[{"id":7415,"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/posts\/4677\/revisions\/7415"}],"wp:attachment":[{"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/media?parent=4677"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/categories?post=4677"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ddmgaragedoors.com\/blog\/wp-json\/wp\/v2\/tags?post=4677"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}